X-ray Fluorescence Spectrometer for Cement Analysis

X-ray Fluorescence Spectrometer for Cement Analysis

 Merchandise Description
It can qualitative and quantitation evaluation among various resources except aspect C, also, the apparatus can overall performance well in Mg,Al,Si,S,P, and Mn which other machine can’t operate properly. It primarily used in the pursuing fields, these kinds of as steel,  fireproofing, non-ferrous sector, the quality division, the plating thickness screening, ROSH inductor analysis and many others.
 Major Characteristics

(1).Correct: Test final results can be near to check wet chemical techniques.

(2).Rapid pace: Testing huge quantities components in the sample only want couple of minutes.

(three).Non-loss: It can not injury the bodily and chemical properties in sample.

(four).Visually: Investigation final results are current directly in graph.

(5).CZPT: It can not pollute the environment.
Principal technical parameter

Evaluation factors Na-U,Mostly are Al,Si,P,S,K,Ca,Ti,V,Fe,Ni,Mn,Pb,Zn,Cu,Sn,Sb,As and so on
examination variety 1 ppm-ninety nine.99%
measuring time All the contents analysis only in 1-two minutes
analysis precision Regular deviation ≤0.08%
evaluation error Up to the normal requirments
radiation dosage <25  μ sv/h
environment temperature fifteen ºC-35 ºC

 Principal allocation

(1). Detection technique

 Detector

 Type: electric powered refrigeration SDD detector

 Be window thickness: 50um

 The ideal resolution: 130eV

 CZPT response assortment: 1keV-50keV

(2).X light tube (for X ray spectrometer)

 Voltage: ~ 50kV

 Maximum existing: one.0mA

 Maximum power: 50W

 Filament voltage: two.0V

 Filament recent: 1.7A

 Ray out angle: twelve °

 Target: Mo

 Be window thickness: .5mm

(3).Substantial-voltage electrical power source

 Input voltage: DC+24V ± ten%

 Input existing: 4.0A ( highest )

 Output voltage: -5KV & 1mA

 Maximum power: 50W

 Voltage regulation charge: .01% ( from no load to full load)

 Current adjustment price: .01% ( from no load to entire load)

 Ripple issue: .1% ( P-P worth)

 The balance of eight hours: .05%

(4). Vacuum pump

 Vacuum: vacuum check 20Pa limit vacuum 2Pa

 (5). Optical integration layout / program / vacuum cavity radiation safety

 X gentle tube, detector, the composite filtertreatment system, CCD, positioning technique, automatic collimator switching program processor optical path are built-in in a closed composition, make sure the security of optical method with a closed optical path program as a vacuum cavity, via the loop and the maze effectively by employing X ray greatest power at the very same time to make certain the ray zero overflow.
Packing & CZPT



 