Screw Compressor Air Cooled Water Chiller Plant

Screw Compressor Air Cooled Water Chiller Plant

CZPT Approach Containerized H2o Chiller Plant

Technical specs
CZPT air cooled h2o chiller
*Higher effiency and welcoming atmosphere
*CE Certificate
*CZPT and heating with heat pump
Apps:
1. Use for cooling products/machine (CZPTtroplating, plastic merchandise, hardware, chemical sector, electronics, meals preservation, laser carving, vacuum coating, ultrasonic cleaning etc industries. )

CZPT Approach Containerized H2o Chiller Plant

CZPT: CZPT, CZPT, Refcomp, consumer can select the compressor
Basic safety creation Unit:
In addition to the features of tank drinking water-cooled machine set, air blast cooling chiller does not want extra cooling h2o tower and is effortless to put in and work so that it is appropriate for modest creation equipments.
Period reversion security, Period lack defense, overload current defense, discharge air temp. CZPT, reduced &large strain security.
Operate:

Refrigerant: R22/R407c/R134, consumer can decide on the refrigerant/gasoline.
one. Undertake the innovative scroll compressor, resistance minimal temp and higher performance
two. CZPTtrical configuration adopt substantial high quality item of the world to make certain that the unit secure high quality and trustworthy procedure.
three. Equipped with higher-overall performance low temp freezing pump and stainless steel h2o tank
four. Adopt the glycol antifreeze as the cooling agent, freezing drinking water temp can be managed at -25 levels Celsius.
five. Client could ask for calcium chloride as an antifreeze.

Parameter of air cooled drinking water chiller

 Air cooled Water Chiller (with Heat Recovery)
     Model     HLWA~ 380DM 420DM 480DM 520DM 560DM 620DM 680DM
380DHM 420DHM 480DHM 520DHM 560DHM 620DHM 680DHM
Rated CZPT Capability X 1000Kcal/h 307.eight 336.2 399. 421.3 460.nine 503.nine 543.4
KW 358 391 464 490 536 586 632
 × Comp. lnput Power×Qty (KW) 58.2×2 63.8×2 70.5×2 74.1×2 eighty two.4×2 ninety.2×2 ninety eight.9×2
Refrigerant  R407C
  Power CZPT  380V/ 3ph/ 50Hz
Basic safety CZPT , , , , , ,
Phase reversion protection, Phase lack defense, Overload current security,
Discharge air temp.  safety, Minimal & Large strain protection, Reduced temp.  safety, H2o movement defense.
  Amount of CZPT Circuit two
Ability Control (%) , twenty five, 37.five, 50, sixty two.5, seventy five, 87.5, one hundred
  Refrigerant Demand (Kg) 104 112 136 142 156 168 186
   Condenser   Ripple Aluminum Fins About Copper Pipe
Evaporator   Dia.of Pipe (inch) 5″ five” three”×2 3″×2 four”×2 four”×2 4″×2
 
Water Facet Max Pressure  (MPa)
1
Chilled  H2o Flow(mthree/h) 61.6 sixty seven.2 seventy nine.eight 84.3 ninety two.2 one hundred.eight 108.7
H2o Strain fall (kPa)  42 fifty four 44 52 fifty four fifty five 65
Axial Supporter ×1000mthree/h
Air Flow×1000m3/h
172.8 172.8 230.four 230.four 230.4 321.6 321.6
× Power×Qty (KW) 1.2×12 one.2×12 1.2×16 1.2×16 one.2×16 two.0×16 two.0×16
  Working Noise dB(A) 72 72 seventy two seventy two 75 75 75
  Whole Weight (Kg) 4430 4550 5340 5420 5500 5860 6320
  Managing Excess weight(Kg) 4750 4970 5800 5950 6040 6480 6900
  Warmth Recovery 
  Refrigerant Demand (Kg) 110 118 142 148 a hundred and sixty 174 192
Warmth Reclaimed Volume (kw) X 1000Kcal/h 92.three one hundred.nine 119.7 126.4 138.3 151.two 163.
KW 107 117 139 147 161 176 a hundred ninety
 Heat Restoration Dia.of Pipe (inch) two-one/2″ 2-1/two” two”×2 two”×2 2″×2 2″×2 2″×2
Drinking water Aspect Max Pressure  (MPa)
Reclaimed  Drinking water Movement (mthree/h) eighteen.5 20.2 23.nine 25.three 27.seven thirty.2 32.6
Water Strain fall (kPa)  26 26 27 27 30 30 34
  Complete Excess weight (Kg) 4790 4910 5920 6040 6260 6480 6980
  Operating Weight(Kg) 5280 5440 6500 6650 6760 7240 7720

Photograph of air cooled h2o chiller

Screw Compressor Air Cooled Water Chiller Plant